3/16/2023 0 Comments Seaiq for ipad![]() Then either OpenCPN or SeaIQ should be displaying AIS targets based on NMEA 0183? What is the process / setup to get it from my NMEA 2000 AIS device into SK and then converted to NMEA 0183? Not seeing any AIS-specific NMEA 0183 sentences in the signalk-to-nmea0183 plugin for that matter, I'm not seeing any NMEA 2000 AIS sentences being logged within SK.Īppreciate your help and patience as I learn.įigured out I needed the signalk-n2kais-to-nmea0183 plugin, and it works! How can you tell by looking at that page that it's about NMEA 0183? I'm learning about all of this fast, but that part isn't self-evident to me (yet). OK, curious - from the app instructions it appeared to me it was all NMEA 2000. Does that info help in terms of configuration of SK to output the data? Per their documentation at only NMEA 2000 is supported. You can achieve what you are after by activating the relevant sk to nmea0183 conversions. Mobile apps usually support only NMEA0183. The message content is the same, but it can be in different formats, like hexadecimal string or base64 encoded, with different delimiters and field separators. If it does you need to find out what format it expects the data to be in, as there are multiple vendor specific formats for n2k data. At least I can not find anything about that in their manual. I don’t think SEAiq supports NMEA2000 data. RE: Send all signalK event to UDP Port (for using navionics on ipad) - tkurki. Except the port access / wifi connection would replace the physical wired connection. The way I understand it, even though SEAiq is on a mobile device connected to the local network (as is OP/SK), it would act as a consumer of AIS data/sentences, as if it was connected via canbus. Specifically, I have an AIS unit that is plugged into NMEA 2000 network, and I would like to see AIS targets in SEAiq. I can see how SK already does that on port 10110 for NMEA0183, but can't figure out how to do the exact same with NMEA2000. I'm looking for apps (ie SEAiq) access NMEA2000 data from the network on a specific port. What exactly are you trying to accomplish - what would be receiving the n2k data and what format does it expect? Unlike 0183 there is no single common format for transmitting n2k data over other media than canbus.Īre you saying the "Signal K to NMEA 2000" is only for "translating" NMEA 0183 to NMEA 2000? (, 05:57 AM)tkurki Wrote: The plugin handles only nmea 0183 data. ![]() (, 09:49 AM)tkurki Wrote: I went ahead and wrote a plugin for this. RE: Send all signalK event to UDP Port (for using navionics on ipad) - Slovak.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |